pyFAI-recalib is now obsolete. All feature provided by it are now available as part of pyFAI-calib.
$ pyFAI-recalib --help
usage: pyFAI-recalib [options] -i ponifile -w 1 -c calibrant.D imagefile.edf
Calibrate the diffraction setup geometry based on Debye-Sherrer rings images
with a priori knowledge of your setup (an input PONI-file). You will need to
provide a calibrant or a "d-spacing" file containing the spacing of Miller
plans in Angstrom (in decreasing order). Calibrants available: Ni, CrOx, NaCl,
Si_SRM640e, Si_SRM640d, Si_SRM640a, Si_SRM640c, alpha_Al2O3, Cr2O3, TiO2,
Si_SRM640, CuO, PBBA, Si_SRM640b, mock, quartz, C14H30O, cristobaltite, Si,
LaB6, CeO2, LaB6_SRM660a, LaB6_SRM660b, LaB6_SRM660c, AgBh, ZnO, Al, Au or
search in the American Mineralogist database:
http://rruff.geo.arizona.edu/AMS/amcsd.php The --calibrant option is mandatory
!
positional arguments:
FILE List of files to calibrate
optional arguments:
-h, --help show this help message and exit
-V, --version show program's version number and exit
-o FILE, --out FILE Filename where processed image is saved
-v, --verbose switch to debug/verbose mode
-c FILE, --calibrant FILE
Calibrant name or file containing d-spacing of the
reference sample (MANDATORY, case sensitive !)
-w WAVELENGTH, --wavelength WAVELENGTH
wavelength of the X-Ray beam in Angstrom. Mandatory
-e ENERGY, --energy ENERGY
energy of the X-Ray beam in keV
(hc=12.398419292keV.A).
-P POLARIZATION_FACTOR, --polarization POLARIZATION_FACTOR
polarization factor, from -1 (vertical) to +1
(horizontal), default is None (no correction),
synchrotrons are around 0.95
-i FILE, --poni FILE file containing the diffraction parameter (poni-file).
MANDATORY for pyFAI-recalib!
-b BACKGROUND, --background BACKGROUND
Automatic background subtraction if no value are
provided
-d DARK, --dark DARK list of comma separated dark images to average and
subtract
-f FLAT, --flat FLAT list of comma separated flat images to average and
divide
-s SPLINE, --spline SPLINE
spline file describing the detector distortion
-D DETECTOR_NAME, --detector DETECTOR_NAME
Detector name (instead of pixel size+spline)
-m MASK, --mask MASK file containing the mask (for image reconstruction)
-n NPT, --pt NPT file with datapoints saved. Default: basename.npt
--filter FILTER select the filter, either mean(default), max or median
-l DISTANCE, --distance DISTANCE
sample-detector distance in millimeter. Default: 100mm
--dist DIST sample-detector distance in meter. Default: 0.1m
--poni1 PONI1 poni1 coordinate in meter. Default: center of detector
--poni2 PONI2 poni2 coordinate in meter. Default: center of detector
--rot1 ROT1 rot1 in radians. default: 0
--rot2 ROT2 rot2 in radians. default: 0
--rot3 ROT3 rot3 in radians. default: 0
--fix-dist fix the distance parameter
--free-dist free the distance parameter. Default: Activated
--fix-poni1 fix the poni1 parameter
--free-poni1 free the poni1 parameter. Default: Activated
--fix-poni2 fix the poni2 parameter
--free-poni2 free the poni2 parameter. Default: Activated
--fix-rot1 fix the rot1 parameter
--free-rot1 free the rot1 parameter. Default: Activated
--fix-rot2 fix the rot2 parameter
--free-rot2 free the rot2 parameter. Default: Activated
--fix-rot3 fix the rot3 parameter
--free-rot3 free the rot3 parameter. Default: Activated
--fix-wavelength fix the wavelength parameter. Default: Activated
--free-wavelength free the wavelength parameter. Default: Deactivated
--tilt Allow initially detector tilt to be refined (rot1,
rot2, rot3). Default: Activated
--no-tilt Deactivated tilt refinement and set all rotation to 0
--saturation SATURATION
consider all pixel>max*(1-saturation) as saturated and
reconstruct them, default: 0 (deactivated)
--weighted weight fit by intensity, by default not.
--npt NPT_1D Number of point in 1D integrated pattern, Default:
1024
--npt-azim NPT_2D_AZIM
Number of azimuthal sectors in 2D integrated images.
Default: 360
--npt-rad NPT_2D_RAD Number of radial bins in 2D integrated images.
Default: 400
--unit UNIT Valid units for radial range: 2th_deg, 2th_rad,
q_nm^-1, q_A^-1, r_mm. Default: 2th_deg
--no-gui force the program to run without a Graphical interface
--no-interactive force the program to run and exit without prompting
for refinements
-r MAX_RINGS, --ring MAX_RINGS
maximum number of rings to extract. Default: all
accessible
-k, --keep Keep existing control point and append new
The main difference with pyFAI-calib is the way control-point hence Debye-
Sherrer rings are extracted. While pyFAI-calib relies on the contiguity of a
region of peaks called massif; pyFAI-recalib knows approximatly the geometry
and is able to select the region where the ring should be. From this region it
selects automatically the various peaks; making pyFAI-recalib able to run
without graphical interface and without human intervention (--no-gui and --no-
interactive options). Note that `pyFAI-recalib` program is obsolete as the
same functionality is available from within pyFAI-calib, using the `recalib`
command in the refinement process. Two option are available for recalib: the
numbe of rings to extract (similar to the -r option of this program) and a new
option which lets you choose between the original `massif` algorithm and newer
ones like `blob` and `watershed` detection.